Check Light
RP-8   Photometric Comparator
Beta Version     1.10
Testing Luminaire ( File Name:  250W-T3-HPS-cobrahead.ies ) to RP-8 lighting standard

Manufact: (left blank) Cat. Number: (left blank)
Filename:(left blank) Test Report: (left blank)
Lumens: Relative Photometry   28500.0 Watts: 297.0
General: Horiz: 180°    Vert: 90° Luminaire Efficacy:  96.0 Lm/W
  The following information is derived from settings and the IES file entered on Page 1.  Settings have ± 2% thresholds.


 Table shows results for filename:   T3-HPS-cobrahead.ies  as an outdoor luminaire mounted at 25 ft.

- - - -  Horizontal° - - - -
 
 22.5° 45° 67.5° 90° 112.5° 135° 157.5° 180° 202.5° 225° 247.5° 270° 292.5° 315° 337.5° 360°  
Vertical  +80° Candella Percentages Classification = Full CutoffThreshold = [%] 
Avg. %     
180°   0.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.0  [0]
135°   0.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.0  [0]
90°   0.00.20.30.20.50.60.30.30.30.30.60.50.20.30.60.00.3  [10]
85°   1.62.73.64.36.35.84.34.74.74.35.86.34.33.611.51.64.7  [10]
  Vertical FC  60" above pavement, radius-feet from light (symmetrical)Horiz
Radius
80°   0.020.020.130.150.070.020.010.020.020.010.020.070.150.130.020.02113 ft
75°   0.220.321.351.220.390.140.140.110.110.140.140.391.221.350.320.2275 ft
70°   0.600.752.512.511.150.630.410.290.290.410.631.152.512.510.750.6055 ft
   
 Horizontal FC on pavement, radius-feet from light @  25-ft height 
80°   0.000.000.010.020.010.000.000.000.000.000.000.010.020.010.000.00142 ft
75°   0.040.050.230.210.070.020.020.020.020.020.020.070.210.230.050.0493 ft
70°   0.140.170.590.590.270.150.100.070.070.100.150.270.590.590.170.1469 ft
65°   0.310.360.951.040.550.340.230.170.170.230.340.551.040.950.360.3154 ft
60°   0.510.691.201.470.870.620.440.330.330.440.620.871.471.200.690.5143 ft
55°   0.791.081.551.771.371.060.800.620.620.801.061.371.771.551.080.7936 ft
45°   2.222.653.543.572.972.321.861.751.751.862.322.973.573.542.652.2225 ft
20°   8.338.768.898.417.656.766.236.056.056.236.767.658.418.898.768.339 ft
 -verse  Longitudinal  Transverse Longitudinal  Trans- 

Min.  = 0.07 fc (underlined)   Avg.  = 1.76 fc (± 15% underlined)  Avg/Min uniformity ratio = 25:1

Red indicates parameter is outside IESNA RP-8 criteria.
Blue > 1/2 min. illuminance can be raised to standard with a like fixture overlapping that coverage line
 Highlighted Blue  Horiz Radius indicates where additional luminaires may be required to meet min. illuminance

Results:
Type:  Symmetrical

Horizontal illuminance at  69.0 feet will limit spacing to less than  138 ft. centers.
Vertical illuminance at  113.0 feet will limit spacing to less than  226 ft. centers.   Vertical illuminance will cause glare.

 Notes
  • The results can suggest maximum spacing of like luminaires required to meet prescribed illumination levels, from which a total count per area may be derived
  • Glare usually results when the luminaire has a significant output level at an angle greater than 70° from the vertical axis.
  • Illuminance is additive. Adjacent luminaire coverage may be overlapped to raise readings up to standard, e.g. if blue print begins at 15-ft, another like luminaire mounted on 30-ft centers with its same side overlapping that same line would double that reading
  • Type-I luminaires have lobes at 0° & 180° OR 90° & 270°. Type-V may have those 4 lobes or have none at all
  • The IESNA Security Lighting Committee recommends that for facial identification, the minumum vertical illuminance should be 0.5 fc
  • The IESNA recommends that vertical illuminance should be at least 1/2 the horizontal illuminance at the lowest unshadowed point between luminaires


This service provides a quick, simple assessment of lighting comparison to ascertain minimum
wattage and luminaire count. The intended purpose is improved data for calculation of ROI and payback.
Seek a thorough lighting layout by a professional before committing a lighting project.